Sealants can prevent, for example, any occasioned damage when rainwater seeps in between tiles on a terrace. As long as they meet certain requirements, these commonly used products can be effective.

DOWNLOAD PDF VERSION

In our laboratories we test adhesives, waterproofing membranes, grouts and now also non-structural sealants. These products require specific certification and CE marking in the European market and UKCA in the UK. 

Balanced Standards: UNE-EN 15651-1, 15651-2, 15651-3 Y 15651-4.

These are the product standards for non-structural sealants use in buildings, according to their purpose:  

  • UNE EN 15651-1:2012: External joints in walls, perimeter joints of windows and doors including the interior-facing side.  
  • UNE EN 15651-2:2012: Joints for glass-glass, glass-frame and glass-porous materials.  
  • UNE EN 15651-3:2012: Joints in sanitary areas inside buildings.  
  • UNE EN 15651-4:2012: Joints in pedestrian areas, public areas, expansion joints between floors, balconies, terraces, warehouses. 

The tests we offerare:   

  • Physical-mechanical: creep, tensile properties, volume loss, elastic recovery.   
  • Reaction to fire

We can also carry out product identification tests for:  

  • Thermogravimetry  
  • Shore hardness  
  • Density
  • VOC emissions

1 Applus+ Laboratories (business name: LGAI T.C.), is an ENAC accredited testing laboratory with accreditation Nº9/LE901 and Nº9/LE985.

Contact us

Applus+ uses first-party and third-party cookies for analytical purposes and to show you personalized advertising based on a profile drawn up based on your browsing habits (eg. visited websites). You can accept all cookies by pressing the "Accept" button or configure or reject their use. Consult our Cookies Policy for more information.