Applus+ around the world
Close Countries Panel
Close Divisions Panel
Applus+ DIVISIONS
Energy & Industry Division
Industrial and environmental inspection, vendor inspection, technical assistance, non-destructive testing (NDT) and technical staffing for all type of industries.
Logo RTD Logo VELOSI Logo NORCONTROL Logo Intec Logo K2
Logo Ingelog Logo JAN Logo Kiefer Logo Novotec Logo NRay
Logo PTJava Logo Skc Logo XRay Logo Qualitec
Laboratories Division
Multidisciplinary laboratories.Testing and engineering for product development. Conformity testing and product certification. SYSTEMS CERTIFICATION.
Logo Applus Laboratories Logo Applus Certification
Automotive Division
Statutory vehicle inspection services and emission & gas testing solutions worldwide.
Logo Applus Automotive Logo Applus ITVE Logo NCT Logo Applus Bilsyn Logo K1
Logo Technologies Logo ITVs Logo Riteve
IDIADA Division
Design, engineering, testing and homologation services for the automotive industry worldwide.
Logo Applus IDIADA

CE Marking of Fire Safety Systems

Ensure conformity of fire alarm and detection systems, smoke and heat control systems, ventilation, ducts and dampers

Safety measures against fire are critical in buildings to reduce any potential risks for people and goods in case of fire. It is quite complex to understand the behavior of the combination of elements involved in a fire.

Construction Products Regulation 305/2011 covers a wide range of products requiring flammability or fire resistance testing. Manufacturers or their representatives are solely responsible for ensuring their product comply with the Regulation provisions. Identifying its product with the CE mark is a manufacturer's statement of compliance with harmonized standards and that the essential requirements of the Regulation have been met.

CE marking of fire protection products is regulated by the Attestation of Conformity (AoC) under systems 1 or 3, which requires the intervention of a Notified Body to perform a Factory Production Control audit and type testing

Solution

Applus+ is a Notified Body* for CE marking and we work with producers throughout the entire CE marking process of their products. CE marking for fire protection products is based on AoC system 1 or 3 and standardized regulations:

Fire alarm and detection systems

 EN 54-1:1996 Fire detection and fire alarm systems  Part 1: Introduction
 EN 54-2:1997
 EN 54-2:1997/AC:1999
 EN 54-2:1996/A1:2006
Fire detection and fire alarm systems - Part 2: Control and indicating equipment
 EN 54-3:2001 &
 EN 54-3:2001/A1:2002
 EN 54-3:2001/A2:2006
Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
 EN 54-4: 1997
 EN 54-4: 1997/AC:1999
 EN 54-4: 1997/A1:2002
 EN 54-4: 1997/A2:2006
Fire detection and fire alarm systems - Part 4: Power supply equipment
 EN 54-5: 2000
 EN 54-5: 2000/A1:2002
Fire detection and fire alarm systems - Part 5: Heat detectors: Point detectors
 EN 54-7: 2000
 EN 54-7: 2000/A1:2002
 EN 54-7: 2000/A2:2006
Smoke detectors: point detectors using scattered light, transmitted light or ionization
 EN 54-11:2001
 EN 54-11:2001/A1:2005
Fire detection and fire alarm systems - Part 11: Manual call points
 EN 54-17:2005
 EN 54-17:2005/AC:2007
Fire detection and fire alarm systems - Part 17: Short-circuit isolators
 EN 54-18:2005
 EN 54-18:2005/AC:2007
Fire detection and fire alarm systems - Part 18: Input/output devices
 EN 54-24:2004 Fire detection and fire alarm systems - Part 24: Components of voice alarm systems: Loudspeakers
 EN 12094-1:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices
 EN 14604:2005
 EN 14604:2005/AC:2008
Smoke alarm devices

Smoke and heat control systems: Ventilation, ducts and dampers 

 EN 12101-3:2002
 EN 12101-3:2002/AC:2005
Smoke and heat control systems - Part 3: Specification for powered smoke and heat exhaust ventilators.
 EN 12101-1:2005
 EN 12101-1:2005/A1:2006
Smoke and heat control systems - Part 1: Specification for smoke barriers
 EN 12101-7:2011 Smoke and heat control systems. Part 7: Smoke duct sections
 EN 15650:2010 Ventilation for buildings - Fire dampers

CE marking defines a number of tasks to be fulfilled by the manufacturer and others by the notified body:

Manufacturer responsibilities:

  • Implementation of Factory Production Control (FPC)
  • Draw up a program of follow-up testing, specifying types, frequencies, etc.

Responsibilities of the notified body, as applicable:

  • Type Testing (mandatory in systems 1 and 3)
  • Initial Factory Production Control (FPC) inspection
  • Continuous survillance, assessment and approval of Factory Production Control (FPC)

CE Marking documents:

  • Test Report (NB)
  • Certificate of Constancy of Performance (NB in System 1)
  • Declaration of Performance (Manufacturer)
  • Labeling and CE marking (Manufacturer)

Applus+ has performed controls on construction products for over 100 years and has completed thousands of tests and product certifications.

* Applus+ is the commercial brand of LGAI Technological Center S.A., Notified Body nº 370.

Benefits

  • One stop shop for testing and the audit of Factory Production Control
  • Improved control over your product and process, thus reducing costs due to low quality.
  • Improved precision and homogeneity in the technical measurement values of your products clearly transmitted to your customers.
  • Market your product throughout the European Union
CE Marking of Fire Safety Systems | Applus+ Laboratories
 
Site map